INSTALLATION AND OPERATION MANUAL
CWFE8MS/DIN
INDUSTRIAL GRADE MANAGED
ETHERNET SWITCH WITH (8) 10/100TX PORTS
V2.0 – March 2011
The ComNet CWFE8MS/DIN Managed Ethernet Switch provides transmission of 10/100 BASE-T Ethernet data.
These units are available for use with conventional CAT-5e copper transmission media. Up to 8 electrical ports
are available for easily implementing point-to-point, linear add-drop, drop-and-repeat, star or true self-healing
ring and mesh network system architectures. The electrical ports support the 10/100 Mbps (10/100 BASE-TX)
Ethernet IEEE 802.3 protocol. Auto-negotiating and auto- MDI/MDIX features are provided for simplicity and ease
of installation. Plug-and-play design ensures ease of installation, and no electrical or optical adjustments are ever
required. The CWFE8MS/DIN incorporates LED indicators for monitoring the operating status of the managed
switch and network.
Zobrazit stránku 0
1 2 3 4 5 6 ... 74 75

Shrnutí obsahu

Strany 1 - CWFE8MS/DIN

INSTALLATION AND OPERATION MANUAL CWFE8MS/DIN INDUSTRIAL GRADE MANAGED ETHERNET SWITCH WITH (8) 10/100TX PORTS V2.0 – March 2011 The ComNet

Strany 2 - CE Mark Warning

4 SNMP MIB RFC 1213 MIBII RFC 1493 Bridge MIB RMON RFC 1757 RFC 2674 VLAN MIB RFC 1643 Ethernet like MIB RFC1215 Trap MIB IGMP MIB. Private MIB for s

Strany 3 - Content

5 Spanning tree IEEE802.1d spanning tree IEEE802.1w rapid spanning tree IGMP IGMP v1 and Query mode Up to 256 groups SNTP Simple network time protoc

Strany 4

6 1.3 Package Contents Please refer to the package content list below and verify product contents against the checklist.  CWFE8MS/DIN managed Et

Strany 5

7 Chapter 2 Hardware Description This section introduces the switch hardware spec, port, cabling information, and wiring installation. 2.1 Physica

Strany 6

8 Reset Button The reset button provides the user with an easy way to restart and reset the configuration back to default value.  Restart: press t

Strany 7 - Chapter 1 Introduction

9 2.4 DIP-switch The switch provides 9 DIP-switches for configuring the relay alarm operational mode and the ring master operational mode. The defa

Strany 8

10 2.5 LED Indicators There are 7 diagnostic LEDs located on the front panel of the commercial switch. They display real-time information about the s

Strany 9 - 1.2 Software Features

11 Chapter 3 Hardware Installation This section describes how to install the CWFE8MS/DIN managed Ethernet switch and the installation points attach

Strany 10

12 3.2 DIN-Rail Mounting The DIN-Rail is attached to the switch when it leaves factory. If the DIN-Rail is not attached to the commercial switch,

Strany 11

13 1. Insert the top of DIN-Rail into the track. 2. Lightly push the DIN-Rail into the track. 3. Check that the DIN-Rail is secured to the

Strany 12 - 1.3 Package Contents

FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules.

Strany 13 - 2.2 Front Panel

14 3.3 Wall Mount Plate Mounting Follow the steps below to mount the switch with a wall mount plate. 1. Remove the DIN-Rail from the industrial sw

Strany 14 - 2.3 Bottom View

15 3.4 Cabling Use eight twisted-pair, Category 5 cables for the RJ-45 port connection. The cable between the converter and the link partner (swit

Strany 15 - 2.4 DIP-switch

16 3.6 Wiring the Fault Alarm Contact The fault-alarm contact is in the middle of the terminal-block connector as the figure shows below. By inser

Strany 16 - 2.5 LED Indicators

17 Chapter 4 Network Application This chapter provides sample applications to help the user to have a better idea of actual switch function applica

Strany 17 - 3.1 Installation Steps

18 4.1 X-Ring Application The CWFE8MS/DIN switch supports the X-Ring protocol that can allow your network system to recover from a network connecti

Strany 18 - 3.2 DIN-Rail Mounting

19 4.2 Coupling Ring Application Within the network there maybe more than one X-Ring group. By using the coupling ring function more than one X-Rin

Strany 19

20 4.3 Dual Homing Application The Dual Homing function is designed to prevent a lost connection between the X-Ring group and upper level/core swit

Strany 20

21 Chapter 5 Web-Based Management This section introduces the configuration and functions of the Web-Based management. The following configuratio

Strany 21 - 3.5 Wiring the Power Inputs

22 5.2 Preparing for Web Management Before using web management, install the switch on the network and make sure that any one of PCs on your networ

Strany 22

23 Login Screen

Strany 23

Content Chapter 1 Introduction...11.1 Hardware Features...

Strany 24 - 4.1 X-Ring Application

24 5.4 System Information  System Description: Display the description of switch. Read only cannot be modified.  Firmware Version: Display the s

Strany 25

25 5.5 Port status Display every port’s status depending on user’s setting and the negotiation result.  Port: the port’s number  Type: the spee

Strany 26 - 4.3 Dual Homing Application

26 5.5.1 Single Port Information Selecting the port on the panel figure on the left side of web page, the user will see the single port information

Strany 27

27 5.6 Port Statistics Display the current port statistic information. Select to clean all counts. Port Statistics Interface 5.7 Port Cont

Strany 28 - 5.3 System Login

28 Duplex mode. The default value is Disable 7. Click button to apply configuration 8. The port’s current configuration is display in column bel

Strany 29 - Login Screen

29 3. Monitor Port: the ports that the user wants to monitor. All monitor port traffic will be copied to the mirror port. A maximum of 7 monitor por

Strany 30 - 5.4 System Information

30 5.9 VLAN configuration A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain that would allow you to isolate netwo

Strany 31 - 5.5 Port status

31 5.9.1 Port-based VLAN Packets can go among only members of the same VLAN group. All unselected ports are treated as belonging to another single

Strany 32 - Port information interface

32 1. Select to add a new VLAN group. The maximum number of VLAN groups is 64. 2. Enter the VLAN name, group ID and group the members of VLAN g

Strany 33 - 5.7 Port Control

33 6. Use button to delete unwanted VLAN groups. 7. Use button to modify an existing VLAN group. Remember to use “Save Configuration”, other

Strany 34 - 5.8 Port Mirroring

3.6 Wiring the Fault Alarm Contact...16Chapter 4 Network Application...

Strany 35 - Prot Mirroring interface

34 5.9.2 802.1Q VLAN Tagged-based VLAN is an IEEE 802.1Q specification standard. It is possible to create a VLAN across devices from different swit

Strany 36 - 5.9 VLAN configuration

35  Basic 1. Select button 2. Management VLAN ID: this is used for Remote Management Security. It includes remote management that includes tel

Strany 37 - 5.9.1 Port-based VLAN

36 802.1q VLAN –Add interface 6. Select Next, and then the page will display as shown below:

Strany 38 - VLAN—PortBase Add interface

37 7. Set the outgoing frames that are VLAN-Tagged frames or untagged, and then select  Tag: outgoing frames with VLAN-Tagged  Untag: outgoin

Strany 39

38 802.1q VLAN – Port VLAN ID interface Remember to use “Save Configuration”, otherwise the new configuration will be lost when the switch is powe

Strany 40 - 5.9.2 802.1Q VLAN

39 5.10 Alert There are three kinds of alerts – e-mail, event, and power alarm. You can configure each alert function, as required. 5.10.1 Email A

Strany 41

40 Email Alert Configuration interface 5.10.2 Event Configuration The selected events that occur will send out the alert to the assigned SMTP serv

Strany 42 - 802.1q VLAN –Add interface

41  Port event selection: Select the per port events. Per port has 3 selections – Link UP, Link Down, and Link UP & Link Down. Disable means no

Strany 43

42 5.10.3 Power Alarm Configuration Power alarm function enables the Relay alarm action. Without enabling the power alarm function, the Relay alarm

Strany 44

43 the network DHCP server will assign the IP address for the switch and display it in this column. The default IP Address is 192.168.16.1.  Subnet

Strany 45 - 5.10 Alert

5.10 Alert ...395.10.1 Email Alert Configuration...

Strany 46 - 5.10.2 Event Configuration

44 7. Daylight Saving Offset (mins): Configure the offset value 8. Synchronization Interval (secs): The Synchronization Interval is used for sendin

Strany 47

45 1. Enable the IP Security: mark the check box to enable the IP security function. 2. Security IP 1 ~ 10: user can assign up to 10 specific IP ad

Strany 48 - 5.11 IP Configuration

46 5.14 RSTP Configuration The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and provides for faster spanning t

Strany 49 - 5.12 SNTP Configuration

47 [NOTE] 1. Must follow the rule to configure the MAX Age, Hello Time, and Forward Delay Time. 2 x (Forward Delay Time value –1) > = Max Ag

Strany 50 - 5.13 IP Security

48 5.14.2 Per Port Configuration Configuring the path cost and priority of every port 1. Select the port in Port column 2. Path Cost: The cost of

Strany 51 - IP Security Interface

49 RSTP – Per Port Configuration interface 5.15 X-Ring X-Ring provides a faster redundant recovery than Spanning Tree topology. The action is sim

Strany 52 - 5.14 RSTP Configuration

50 backup port will automatically become a working port to recover from the failure. The switch supports one Dipswitch for configuring the switch as

Strany 53

51 X-Ring Interface [NOTE] 1. When the X-Ring function is enabled, RSTP has to be disabled. The X-Ring function and RSTP function cannot be activ

Strany 54

52  Port-base: the port priority will follow the default port priority that the user has assigned – High, middle, low, or lowest  COS only: the p

Strany 55 - 5.15 X-Ring

53 QoS configuration Interface

Strany 56

5.20.1 TFTP Restore Configuration...585.20.2 TFTP Backup Configuration ...

Strany 57 - 5.16 QoS Configuration

54 5.17 IGMP The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. IP manages multicast traffi

Strany 58

55 IGMP Snooping interface 5.18 Security Manager Changing the web management login user name and password for the management security issue 1. Us

Strany 59 - QoS configuration Interface

56 5.19 SNMP Configuration The SNMP is a Protocol that governs the transfer of information between management and agent. The switch supports SNMP V1

Strany 60 - 5.17 IGMP

57 5.19.3 Trap Manager A trap manager is a management station that receives traps that are the system alerts generated by the switch. If no trap ma

Strany 61 - 5.18 Security Manager

58 5.20 Configuration Backup Restore the backup configuration back to the CWFE8MS/DIN and backup the switch configuration to TFTP server. 5.20.1

Strany 62 - 5.19 SNMP Configuration

59 2. Backup File Name: Enter the file name 3. Select TFTP Backup Configuration interface 5.21 TFTP Update Firmware Updating the switch’s firm

Strany 63 - 5.19.3 Trap Manager

60 5.22 Factory Default Resetting the switch to the default configuration. The IP address, subnet mask, default gateway, username, and password wi

Strany 64 - 5.20 Configuration Backup

61 5.24 System Reboot Reboot the switch in software reset. Select button to reboot the switch. System Reboot interface 5.25 Rate Control Se

Strany 65 - 5.21 TFTP Update Firmware

62 [NOTE] 1. Remember to execute the “Save Configuration”, otherwise the new configuration will be lost when the switch is powered off. 2. QoS and

Strany 66 - 5.23 Save Configuration

63  System Log Client Mode: Select in Client Only, Server Only, or Both mode  System Log Server IP: Assign the system log server IP address  Se

Strany 67 - 5.25 Rate Control

1 Chapter 1 Introduction The CWFE8MS/DIN managed Ethernet switch is a cost-effective solution and meets the high reliability requirements demanded

Strany 68 - 5.26 System Log

64 5.26.2 Event Configuration Select the system log events. When selected events occur, the system will send out the log information. Also, per por

Strany 69

65 Event Configuration interface

Strany 70 - 5.26.2 Event Configuration

66 Trouble Shooting  Verify that is using the right power cord/adapter (DC 12-48V), do not use a power adapter with DC voltage output greater tha

Strany 71

67 Appendix A-RJ45 Pin Assignment  RJ-45 ports There are 8x 10/100Mbps auto-sensing electrical ports for 10Base-T or 100Base-TX devices connec

Strany 72 - Trouble Shooting

68 Pin MDI-X Signal Name MDI Signal Name 1 Receive Data plus (RD+) Transmit Data plus (TD+) 2 Receive Data minus (RD-) Transmit Data minus (T

Strany 73

69 Technical Support The ComNet Technical Support and Design Center provides technical pre-sale and post-sale support for Ethernet transmission netw

Strany 74 - Cross Over Cable Schematic

2 Back-plane 1.6 Gbps Packet throughput ability 2.38Mpps @64bytes (8TX) LED Per port: Link/Activity (Green), Full duplex/Collision (Yellow) Per unit

Strany 75

3 Operation Humidity 5% to 95% (Non-condensing) Storage Temperature -40 to 85 Case Dimension IP-30, 54 mm (W) x 135 mm (H) x 105mm (D) EMI FCC Cl

Komentáře k této Příručce

Žádné komentáře